SOLASII-2 part C 10.4.3: 4.3 Storage rooms of fire extinguishing medium When the fire extinguishing medium is stored outside a protected space, it shall be stored in a room which is located behind the forward collision bulkhead, and is used for no other purposes. Any entrance to such a storage room shall preferably be from the open deck and shall be independent of the protected space. If the storage space is located below deck, it shall be located no more than one deck below the open deck and shall be directly accessible by a stairway or ladder from the open deck. Spaces which are located below deck or spaces where access from the open deck is not provided, shall be fitted with a mechanical ventilation system designed to take exhaust air from the bottom of the space and shall be sized to provide at least 6 air changes per hour. Access doors shall open outwards, and bulkheads and decks including doors and other means of closing any opening therein, which form the boundaries between such rooms and adjacent enclosed spaces shall be gastight. For the purpose of the application of tables 9.1 to 9.8, such storage rooms shall be treated as fire control stations. 這段文字有點(diǎn)長,是用來規(guī)定滅火劑儲(chǔ)存室的,分兩種情況一個(gè)是存儲(chǔ)室位于甲板以上,一個(gè)是儲(chǔ)存室位于甲板一下。網(wǎng)友提供的問題顯然是涉及甲板以上的規(guī)定。 1、該處所應(yīng)獨(dú)立于被保護(hù)處所( be independent of the protected space) 2、防撞艙壁之后(it shall be stored in a room which is located behind the forward collision bulkhead) 3、開口盡可能開向開敞甲板(Any entrance to such a storage room shall preferably be from the open deck) 注意第三條有個(gè)詞preferably:adv. 更可取地; 更好地, 顯然公約的本意是希望大家這么布置的,網(wǎng)友的問題說有兩個(gè)門,第一個(gè)門是水密門(個(gè)人覺得八成是風(fēng)雨密門),這個(gè)顯然滿足要求。另一個(gè)門是一個(gè)位于生活區(qū)朝內(nèi)開的防火門,顯然設(shè)置開向生活區(qū)的門違背上述公約的本意;再者如果從逃生的角度分析也不能向內(nèi)開(SOLASII-2 13.3.1.5:3.1.5 Doors in escape routes shall, in general, open in-way of the direction of escape),所以這道門應(yīng)該是不滿足要求的。 |
|
|